{"id":3152,"date":"2024-12-18T20:00:23","date_gmt":"2024-12-18T20:00:23","guid":{"rendered":"https:\/\/veraqueconsulting.com\/co\/?p=3152"},"modified":"2025-06-30T19:50:16","modified_gmt":"2025-06-30T19:50:16","slug":"classification-and-grouping-of-pacemakers-in-colombia","status":"publish","type":"post","link":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/","title":{"rendered":"Classification and Grouping of Pacemakers in Colombia"},"content":{"rendered":"<p><span data-contrast=\"none\">Pacemakers have\u00a0been considered an important precursor of many developments in science and cardiac medicine, playing a unique role in managing heart rhythm disorders. These medical devices can greatly improve the quality of life for individuals with heart rhythm disorders by reducing symptoms such as fatigue, dizziness, and fainting. They also help prevent serious complications associated with untreated bradycardia or arrhythmias.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">This article will explore the features and uses of different pacemaker types, along with providing advice on how they are categorized and grouped according to the regulatory standards in Colombia.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<h3><b><span data-contrast=\"none\">Structure and Uses of Pacemakers<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:120,&quot;335559739&quot;:240}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Pacemakers are devices used to treat some types of <a href=\"https:\/\/www.nhlbi.nih.gov\/health\/arrhythmias#:~:text=An%20arrhythmia%2C%20or%20irregular%20heartbeat,or%20with%20an%20irregular%20rhythm.\" target=\"_blank\" rel=\"noopener\">arrhythmias<\/a>. When an arrhythmia happens, the heart goes through a modified electric cycle, and it starts beating in an irregular fashion. A pacemaker sends a low-energy electrical impulse to the heart muscle, helping it to beat at a normal rate and rhythm. They can also be used to help people with heart failure, by allowing heart chambers to beat synchronously and improve the efficiency of blood pumping to the body.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Traditional pacemakers have three main parts:<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"20\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><b><span data-contrast=\"none\">The pulse generator<\/span><\/b><span data-contrast=\"none\"> is the main unit of the pacemakers, containing the electronic circuitry and programmable settings. The pulse generator is responsible for generating and delivering the electrical impulses to the heart.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"20\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><b><span data-contrast=\"none\">The electrodes<\/span><\/b><span data-contrast=\"none\"> (also called leads or wires) are insulated wires that carry the electrical impulses from the pulse generator to the heart muscle. The number of electrodes depends on the type of pacemaker.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"20\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><b><span data-contrast=\"none\">The<\/span><\/b> <b><span data-contrast=\"none\">battery<\/span><\/b><span data-contrast=\"none\"> provides the energy needed to generate and deliver the electrical impulses over the device\u2019s lifespan, which can range from several years to over a decade.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><b><span data-contrast=\"none\">Types of Pacemakers<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:120,&quot;335559739&quot;:240}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">As a first type of pacemaker distinction, we can talk about two types of pacemakers:<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"21\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><b><span data-contrast=\"none\">External pacemakers: <\/span><\/b><span data-contrast=\"none\">also known as temporary pacemakers, are non-invasive devices used on a short-term basis to manage temporary heart rhythm abnormalities. They are typically used in emergency situations or during procedures where temporary pacing support is needed. External pacemakers are connected to the patient\u2019s chest using electrode pads placed on the skin. These devices are not implanted and are removed once the underlying rhythm issue is resolved, or a permanent pacemaker is implanted.<\/span>&nbsp;<\/li>\n<\/ul>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"21\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><b><span data-contrast=\"none\">Implantable pacemakers: <\/span><\/b><span data-contrast=\"none\">these are surgically implanted devices designed for long-term management of chronic heart rhythm disorders. They are placed under the skin in the chest area, with leads connected to the heart\u2019s chambers. Implantable pacemakers can be single-chamber, dual-chamber, or biventricular devices.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li data-leveltext=\"o\" data-font=\"Courier New\" data-listid=\"21\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:1440,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Courier New&quot;,&quot;469769242&quot;:[9675],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;o&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"2\"><b><span data-contrast=\"none\">Single-Chamber Pacemakers: <\/span><\/b><span data-contrast=\"none\">These pacemakers have one lead (thin wire) connected to either the atrium (upper chamber) or ventricle (lower chamber) of the heart. Single-chamber pacemakers are used when the abnormal heart rhythm originates in either the atrium or ventricle, but not both.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li data-leveltext=\"o\" data-font=\"Courier New\" data-listid=\"21\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:1440,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Courier New&quot;,&quot;469769242&quot;:[9675],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;o&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"2\" data-aria-level=\"2\"><b><span data-contrast=\"none\">Dual-Chamber Pacemakers: <\/span><\/b><span data-contrast=\"none\">Dual-chamber pacemakers have two leads, one placed in the atrium and the other in the ventricle. These devices can coordinate the timing of electrical impulses between the atrium and ventricle, mimicking the heart\u2019s natural electrical conduction system more closely.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li data-leveltext=\"o\" data-font=\"Courier New\" data-listid=\"21\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:1440,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Courier New&quot;,&quot;469769242&quot;:[9675],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;o&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"3\" data-aria-level=\"2\"><b><span data-contrast=\"none\">Biventricular Pacemakers (Cardiac Resynchronization Therapy \u2013 CRT): <\/span><\/b><span data-contrast=\"none\">Biventricular pacemakers are used for individuals with heart failure and specific types of electrical conduction abnormalities. They have three leads\u2014one in the right atrium, one in the right ventricle, and a third lead placed in the left ventricle via a coronary sinus vein. Biventricular pacemakers help synchronize the contractions of the heart\u2019s ventricles to improve pumping efficiency.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><b><span data-contrast=\"none\">Classification and Grouping of Pacemakers<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:120,&quot;335559739&quot;:240}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Depending on their type, pacemakers fall under two classifications according to the Colombian regulatory framework. Implantable pacemakers fall under <\/span><b><span data-contrast=\"none\">Class III<\/span><\/b><span data-contrast=\"none\"> medical devices because the device is implantable and used in direct contact with the heart. On the other hand, external pacemakers fall under <\/span><b><span data-contrast=\"none\">Class IIb.<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">As we outline in our <\/span><a href=\"https:\/\/veraqueconsulting.com\/co\/guides\/device-classification-and-device-grouping-colombia\/\" target=\"_blank\" rel=\"noopener\"><span data-contrast=\"none\">Classification and Grouping Ultimate Guide<\/span><\/a><span data-contrast=\"none\">, based on article 28 of Decree 4725 of 2005\u00a0multiple models of a device\u00a0might be grouped in the same registration, as long as they share: <\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"22\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Same device classification <\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"22\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Same intended use<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"22\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Same distinctive denomination (commercial name)<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"22\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Same manufacturer<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"none\">\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">If you have any inquiries about the registration of pacemakers or any other medical devices in the Colombian market, please feel free to contact us at <\/span><a href=\"mailto:contact@veraqueconsulting.com\"><span data-contrast=\"none\">contact@veraqueconsulting.com<\/span><\/a><span data-contrast=\"none\">, or check our <\/span><a href=\"https:\/\/veraqueconsulting.com\/co\/guides\/\" target=\"_blank\" rel=\"noopener\"><span data-contrast=\"none\">guidelines.<\/span><\/a><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559738&quot;:0,&quot;335559739&quot;:216}\">\u00a0<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pacemakers have\u00a0been considered an important precursor of many developments in science and cardiac medicine, playing a unique role in managing heart rhythm disorders. These medical devices can greatly improve the quality of life for individuals with heart rhythm disorders by reducing symptoms such as fatigue, dizziness, and fainting. They also help prevent serious complications associated [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":3153,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[367,396],"tags":[],"class_list":["post-3152","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-classification","category-colombia"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Classification and Grouping of Pacemakers in Colombia - Veraque Colombia<\/title>\n<meta name=\"description\" content=\"This article provides a detailed analysis of regulatory standards and classification rules for pacemakers in Colombia.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Classification and Grouping of Pacemakers in Colombia\" \/>\n<meta property=\"og:description\" content=\"This article provides a detailed analysis of regulatory standards and classification rules for pacemakers in Colombia.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/\" \/>\n<meta property=\"og:site_name\" content=\"Veraque Colombia\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-18T20:00:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-30T19:50:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2024\/12\/classification_pacemakers_colombia.png\" \/>\n\t<meta property=\"og:image:width\" content=\"940\" \/>\n\t<meta property=\"og:image:height\" content=\"788\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"mkt1\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"mkt1\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/\"},\"author\":{\"name\":\"mkt1\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#\\\/schema\\\/person\\\/3f760cd8f7128ca81c70930dcfcc1e44\"},\"headline\":\"Classification and Grouping of Pacemakers in Colombia\",\"datePublished\":\"2024-12-18T20:00:23+00:00\",\"dateModified\":\"2025-06-30T19:50:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/\"},\"wordCount\":698,\"publisher\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2024\\\/12\\\/classification_pacemakers_colombia.png\",\"articleSection\":[\"classification\",\"Colombia\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/\",\"url\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/\",\"name\":\"Classification and Grouping of Pacemakers in Colombia - Veraque Colombia\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2024\\\/12\\\/classification_pacemakers_colombia.png\",\"datePublished\":\"2024-12-18T20:00:23+00:00\",\"dateModified\":\"2025-06-30T19:50:16+00:00\",\"description\":\"This article provides a detailed analysis of regulatory standards and classification rules for pacemakers in Colombia.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#primaryimage\",\"url\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2024\\\/12\\\/classification_pacemakers_colombia.png\",\"contentUrl\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2024\\\/12\\\/classification_pacemakers_colombia.png\",\"width\":940,\"height\":788,\"caption\":\"pacemaker placed over a hand, classification pacemakers Colombia\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/classification-and-grouping-of-pacemakers-in-colombia\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Classification and Grouping of Pacemakers in Colombia\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#website\",\"url\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/\",\"name\":\"Veraque Colombia\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#organization\",\"name\":\"Veraque Colombia\",\"url\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2019\\\/11\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2019\\\/11\\\/logo.png\",\"width\":450,\"height\":105,\"caption\":\"Veraque Colombia\"},\"image\":{\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/#\\\/schema\\\/person\\\/3f760cd8f7128ca81c70930dcfcc1e44\",\"name\":\"mkt1\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce58fed175315752b10e7604ce713dd9a941e8c2800a89102729df3452b82236?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce58fed175315752b10e7604ce713dd9a941e8c2800a89102729df3452b82236?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce58fed175315752b10e7604ce713dd9a941e8c2800a89102729df3452b82236?s=96&d=mm&r=g\",\"caption\":\"mkt1\"},\"url\":\"https:\\\/\\\/veraqueconsulting.com\\\/co\\\/author\\\/mkt1\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Classification and Grouping of Pacemakers in Colombia - Veraque Colombia","description":"This article provides a detailed analysis of regulatory standards and classification rules for pacemakers in Colombia.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/","og_locale":"en_US","og_type":"article","og_title":"Classification and Grouping of Pacemakers in Colombia","og_description":"This article provides a detailed analysis of regulatory standards and classification rules for pacemakers in Colombia.","og_url":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/","og_site_name":"Veraque Colombia","article_published_time":"2024-12-18T20:00:23+00:00","article_modified_time":"2025-06-30T19:50:16+00:00","og_image":[{"width":940,"height":788,"url":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2024\/12\/classification_pacemakers_colombia.png","type":"image\/png"}],"author":"mkt1","twitter_card":"summary_large_image","twitter_misc":{"Written by":"mkt1","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#article","isPartOf":{"@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/"},"author":{"name":"mkt1","@id":"https:\/\/veraqueconsulting.com\/co\/#\/schema\/person\/3f760cd8f7128ca81c70930dcfcc1e44"},"headline":"Classification and Grouping of Pacemakers in Colombia","datePublished":"2024-12-18T20:00:23+00:00","dateModified":"2025-06-30T19:50:16+00:00","mainEntityOfPage":{"@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/"},"wordCount":698,"publisher":{"@id":"https:\/\/veraqueconsulting.com\/co\/#organization"},"image":{"@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#primaryimage"},"thumbnailUrl":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2024\/12\/classification_pacemakers_colombia.png","articleSection":["classification","Colombia"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/","url":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/","name":"Classification and Grouping of Pacemakers in Colombia - Veraque Colombia","isPartOf":{"@id":"https:\/\/veraqueconsulting.com\/co\/#website"},"primaryImageOfPage":{"@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#primaryimage"},"image":{"@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#primaryimage"},"thumbnailUrl":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2024\/12\/classification_pacemakers_colombia.png","datePublished":"2024-12-18T20:00:23+00:00","dateModified":"2025-06-30T19:50:16+00:00","description":"This article provides a detailed analysis of regulatory standards and classification rules for pacemakers in Colombia.","breadcrumb":{"@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#primaryimage","url":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2024\/12\/classification_pacemakers_colombia.png","contentUrl":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2024\/12\/classification_pacemakers_colombia.png","width":940,"height":788,"caption":"pacemaker placed over a hand, classification pacemakers Colombia"},{"@type":"BreadcrumbList","@id":"https:\/\/veraqueconsulting.com\/co\/classification-and-grouping-of-pacemakers-in-colombia\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/veraqueconsulting.com\/co\/"},{"@type":"ListItem","position":2,"name":"Classification and Grouping of Pacemakers in Colombia"}]},{"@type":"WebSite","@id":"https:\/\/veraqueconsulting.com\/co\/#website","url":"https:\/\/veraqueconsulting.com\/co\/","name":"Veraque Colombia","description":"","publisher":{"@id":"https:\/\/veraqueconsulting.com\/co\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/veraqueconsulting.com\/co\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/veraqueconsulting.com\/co\/#organization","name":"Veraque Colombia","url":"https:\/\/veraqueconsulting.com\/co\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/veraqueconsulting.com\/co\/#\/schema\/logo\/image\/","url":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2019\/11\/logo.png","contentUrl":"https:\/\/veraqueconsulting.com\/co\/wp-content\/uploads\/sites\/4\/2019\/11\/logo.png","width":450,"height":105,"caption":"Veraque Colombia"},"image":{"@id":"https:\/\/veraqueconsulting.com\/co\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/veraqueconsulting.com\/co\/#\/schema\/person\/3f760cd8f7128ca81c70930dcfcc1e44","name":"mkt1","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ce58fed175315752b10e7604ce713dd9a941e8c2800a89102729df3452b82236?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ce58fed175315752b10e7604ce713dd9a941e8c2800a89102729df3452b82236?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ce58fed175315752b10e7604ce713dd9a941e8c2800a89102729df3452b82236?s=96&d=mm&r=g","caption":"mkt1"},"url":"https:\/\/veraqueconsulting.com\/co\/author\/mkt1\/"}]}},"_links":{"self":[{"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/posts\/3152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/comments?post=3152"}],"version-history":[{"count":1,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/posts\/3152\/revisions"}],"predecessor-version":[{"id":3227,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/posts\/3152\/revisions\/3227"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/media\/3153"}],"wp:attachment":[{"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/media?parent=3152"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/categories?post=3152"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/veraqueconsulting.com\/co\/wp-json\/wp\/v2\/tags?post=3152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}